DD15 SPN 164/FMI 0 Troubleshooting

SPN 164/FMI 0

This fault condition indicates a Quantity Control Valve High Side driver error. This condition can occur when:‪

  • MCM pin 1 circuit is shorted to ground
  • Internal short of the Quantity Control Valve

Check as follows:‪

  1. Check for multiple codes
    1. If 164/1 is stored along with 164/0, service 164/1 first.
    2. If only 164/0 is active, go to the next step.
  2. Disconnect the Quantity Control Valve harness connector.
  3. Ensure the multi meter (DVOM) resistance is zero.
    1. If meter can auto zero, perform this function before making a resistance measurement.
    2. If meter can not auto zero, note the resistance of the leads and subtract it from the measurement taken in step 4
  4. Measure the resistance across pins 1 and 2 of the Quantity Control Valve.
    1. If the resistance is less than 1.3 Ω, replace Quantity Control Valve. Refer to “31.1.1 Verify Repairs” .
    2. If the resistance is between 1.3 Ω and 1.4 Ω, go to next step.
  5. Disconnect the 120-pin MCM connector and check for corroded, bent or broken pins. Ensure both the MCM and harness connector pins are checked. Repair or replace if needed.
  6. Measure the resistance between pin 1 of the Quantity Control Valve harness connector and ground.
    1. If the resistance is greater than 5 Ω, replace Quantity Control Valve. Refer to “31.1.1 Verify Repairs” .
    2. If the resistance is less than 5 Ω, repair the short circuit between pin 1 of the Quantity Control Valve and ground.