SPN 164/FMI 0
This fault condition indicates a Quantity Control Valve High Side driver error. This condition can occur when:
- MCM pin 1 circuit is shorted to ground
- Internal short of the Quantity Control Valve
Check as follows:
- Check for multiple codes
- If 164/1 is stored along with 164/0, service 164/1 first.
- If only 164/0 is active, go to the next step.
- Disconnect the Quantity Control Valve harness connector.
- Ensure the multi meter (DVOM) resistance is zero.
- If meter can auto zero, perform this function before making a resistance measurement.
- If meter can not auto zero, note the resistance of the leads and subtract it from the measurement taken in step 4
- Measure the resistance across pins 1 and 2 of the Quantity Control Valve.
- If the resistance is less than 1.3 Ω, replace Quantity Control Valve. Refer to “31.1.1 Verify Repairs” .
- If the resistance is between 1.3 Ω and 1.4 Ω, go to next step.
- Disconnect the 120-pin MCM connector and check for corroded, bent or broken pins. Ensure both the MCM and harness connector pins are checked. Repair or replace if needed.
- Measure the resistance between pin 1 of the Quantity Control Valve harness connector and ground.
- If the resistance is greater than 5 Ω, replace Quantity Control Valve. Refer to “31.1.1 Verify Repairs” .
- If the resistance is less than 5 Ω, repair the short circuit between pin 1 of the Quantity Control Valve and ground.