SPN 174/FMI 4
SPN 174, PID 174/FMI 4 indicates a SFT Sensor short circuit to ground.
Check as follows:
- Disconnect the SFT Sensor.
- Disconnect the 120-pin MCM connector.
- Measure the resistance across pins 1 and 2 of the SFT Sensor connector.
- If resistance is less than 5 Ω, repair short between wires 55 and 77 of the 120-pin MCM connector. Refer to “34.3.1 Verify Repairs” .
- If resistance is greater than 5 Ω, go to the next step.
- Measure the resistance between pin 1 of the SFT Sensor harness connector and ground.
- If resistance is less than 5 Ω, repair the short circuit between pin 1 of the SFT Sensor harness connector and ground. Refer to “34.3.1 Verify Repairs” .
- If resistance is greater than 5 Ω, go to the next step.
- Measure the resistance between pin 2 of the SFT Sensor harness connector and ground.
- If resistance is less than 5 Ω, repair the short circuit between pin 2 of the SFT Sensor harness connector and ground. Refer to “34.3.1 Verify Repairs” .
- If resistance is greater than 5 Ω, review steps 3 through 5 . If the results are the same, contact Detroit Diesel Customer Support Center at 313-592-5800.
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
ENGINE EXHAUST To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. - Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes.