DD15 SPN 647/FMI 3 Troubleshooting

SPN 647/FMI 3

This fault code indicates that there is a short to power.‪

Check as follows:‪

  1. Turn the ignition OFF.
  2. Disconnect the fan control solenoid connector.
  3. Turn the ignition ON (key On, engine OFF).
  4. Measure the voltage between pin 1 of the fan control solenoid connector and ground.
    1. If the voltage is greater than 11.5 volts, repair the short to power between pin 1 of the fan control solenoid connector and pin 98 of the 120–pin MCM connector. Refer to “57.1.1 Verify Repairs” .
    2. If the voltage is less than 11.5 volts, replace the fan control solenoid. Refer to “57.1.1 Verify Repairs” .

Verify Repairs

Verify repairs as follows:‪

  1. Turn ignition OFF.
  2. Reconnect any electrical connections that were disconnected to perform the diagnosis.
  3. Clear codes with DDDL 7.0 or latest version.
    ENGINE EXHAUST ‪
    To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic.‪
  4. Start and bring engine up to operating temperature (over 140°F/60°C).
  5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes.