Series 60 – SPN 1636/FMI 31 – INTAKE AIR TEMPERATURE OUTSIDE OF NORMAL OPERATING RANGE

This diagnosis is typically the difference between intake manifold temperature dand EGR
temperature is less than threshold (low box).
87.5.1
Temperature Difference Check
Check as follows:
1. Inspect the entire air intake system including the CAC for leaks, cracks or plugging.
[a] If damage is found, repair as necessary. Refer to section 87.5.1.1.
[b] If no damage is found, go to step 2.
2. Disconnect the Intake Manifold Temperature Sensor.
3. Inspect the Intake Manifold Temperature Sensor connectors for bent, spread or corroded
pins.
[a] If pin damage is found, repair as necessary. Refer to section 87.5.1.1.
[b] If no pin damage is found, replace the Intake Manifold Temperature Sensor.
Refer to section 87.5.1.1.

Leave a Reply

Your email address will not be published. Required fields are marked *