DD15 SPN 2623/FMI 4 Troubleshooting

SPN 2623/FMI 4

This fault is typically the PWM Accelerator Pedal J1939 GAS2 signal is missing.‪

Check as follows:‪

  1. Check for multiple codes:
    1. If CPC SPN 168/FMI 0/14/18 (Battery Voltage) are present troubleshoot these first.
    2. If MCM SPN 625/FMI 9 is present, troubleshoot and repair the CAN line.
    3. If only a “J1939 Error” fault is present, go to the next step.
  2. Has the CPC been recently reprogrammed?
    1. If yes, check the proper configuration of the CPC.
    2. If no, connect ServiceLink to determine which modules are configured for the vehicle and their communication status. Once this is done, follow the appropriate module communication troubleshooting procedures for the affected module.

Leave a Reply

Your email address will not be published. Required fields are marked *