DD15 Defective Magnetic Switch

Check as follows:‪

warningENGINE EXHAUST ‪
To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic.‪
  1. Clamp a heavy gage battery jumper cable between the two large studs of the magnetic switch (1). Try to start the engine.
    Click to see this graphic in a separate window
    1. If the engine cranked with the jumper cable in place, the magnetic switch must be replaced; go to step 3 .
    2. If the engine did not crank with the jumper cable in place, check the starter; refer to “2.3 Defective Starter” .
  2. Replace the magnetic switch (1). Refer to OEM guidelines.
    warningENGINE EXHAUST ‪
    To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic.‪
  3. To determine if the magnetic switch replacement resolved the no start condition, attempt to start and run the engine.
    1. If the engine starts and runs, no further troubleshooting is required. Shut down the engine.
    2. If the engine fails to start or rotate, check the starter; refer to “2.3 Defective Starter” .