Series 60 – FAN CONTROL – DDEC VI SCHEMATICS

129.2 FAN CONTROL
DDEC VI provides fan control for four different fan configurations.
129.2.1 Single-speed Fan – Fan Type 4
This fan type must be used if the current exceeds 2A. See Figure 129-2.

apic1 6 Series 60   FAN CONTROL   DDEC VI SCHEMATICS

129.2.2 Single-speed Fan – Fan Type 7
This fan type can be used if the current is less than 2.0 A. See Figure 129-3.

apic1 7 Series 60   FAN CONTROL   DDEC VI SCHEMATICS

129.2.3 Dual Fan – Fan Type 6
The two fans are independent of one another and are controlled by different conditions. Both
fans will be activated when either the Fan Control Override is enabled or when the conditions are
met for Fan Engine Brake. See Figure 129-4.

apic1 8 Series 60   FAN CONTROL   DDEC VI SCHEMATICS

129.2.4 Two-speed Fan – Fan Type 0 or 1
This configuration uses two digital outputs, Fan Control #1 and Fan Control #2, to drive a
two-speed fan. See Figure 129-5.

apic1 10 Series 60   FAN CONTROL   DDEC VI SCHEMATICS

129.2.5 Variable Speed Fan without Fan Speed Feedback – Fan Type 3
DDEC VI uses a pulse width modulated (PWM) output to drive a variable speed fan. See Figure
129-6

apic1 11 Series 60   FAN CONTROL   DDEC VI SCHEMATICS

129.2.6 Variable Speed Fan with Fan Speed Feedback – Fan Type 2
DDEC VI uses a pulse width modulated (PWM) output to drive a variable speed fan. See Figure
129-7.

apic1 12 Series 60   FAN CONTROL   DDEC VI SCHEMATICS

Leave a Reply