Troubleshooting SID 233
Perform the following steps to troubleshoot SID 233:
233 12 – PLD-MR Failed or Programmed Incorrectly
Troubleshoot a PLD-MR failed or programmed incorrectly fault as follows:
- Reset the parameters on the PLD-MR.
- If fault code 233 12 is not active after resetting parameters, stop. Fault code has been cleared.
- If fault code 233 12 is still active after resetting parameters, go to step 2 .
- Check PLD parameters to ensure they are correct for the vehicle configuration.
- If parameters are not correct, reset parameters on the PLD-MR.
- If parameters are correct, contact Detroit Diesel Technical Service for authorization to replace the PLD-MR. Set parameters on the new PLD-MR.
233 14 – Incorrect or Misprogrammed PLD-MR
Troubleshoot an incorrect or misprogrammed PLD-MR as follows:
- Check to ensure the PLD-MR is correct for the engine.
- If PLD-MR is correct for the engine, go to step 2 .
- If PLD-MR is not correct for the engine, contact Detroit Diesel Technical Service for authorization to replace the PLD-MR. Set parameters on the new PLD-MR.
- Reset the PLD parameters.
- If fault code 233 14 is not active after PLD parameters are reset, stop. Fault code has been cleared.
- If fault code 233 14 is still active after PLD parameters are reset, go to step 3 .
- Check PLD parameters to ensure they are correct for the vehicle configuration.
- If PLD parameters are not correct, reset parameters on PLD-MR. Erase fault code memory.
- If PLD parameters are correct, contact Detroit Diesel Technical Service for authorization to replace the PLD-MR. Set parameters on the new PLD-MR.