MBE 900/4000 SID 230 – Throttle Control Fault

Description of SID 230 – Throttle Control Fault

SID 230 indicates that a fault has occurred in the throttle control.‪

The diagnostic condition is typically:‪

  • Idle Validation Switch Open Circuit (230 05)
  • Idle Validation Switch Short to Ground (230 12)

Accelerator Pedal – The accelerator pedal (AP) sends an input signal which the DDEC-VCU uses to calculate engine power proportional to the foot pedal position. See Figure “Location of DDEC-VCU and Wiring Harness Connectors” . This assembly is also referred to as the AP Sensor assembly.‪

 1. Right-Side Dash‪  4. 18-Pin Connector‪
 2. DDEC-VCU‪  5. 21-Pin Connector‪
 3. 15-Pin Connector‪  ‪

Figure 1. Location of DDEC-VCU and Wiring Harness Connectors

Accelerator Pedal Installation– MBE electronic controls are compatible with an AP which has an output voltage that meets SAE J1843 and has less than 5% of voltage supply closed throttle variability. See Figure “Typical Accelerator Pedal Installation” .‪

Figure 2. Typical Accelerator Pedal Installation

The AP is an OEM-supplied part. Vendor sources may be contacted for additional design and installation details.‪