MBE 900/4000

MBE 900/4000 SID 230 Troubleshooting

Posted on October 17, 2023 by sam

Troubleshooting SID 230 The following procedures will troubleshoot SID 230.‪ 230 05 – Idle Validation Switch Open Circuit Fault Perform the following steps to troubleshoot…

MBE 900/4000

MBE 900/4000 SID 232 – Accelerator Pedal Supply Voltage Fault

Posted on October 17, 2023 by sam

Description of SID 232 – Accelerator Pedal Supply Voltage Fault SID 232 indicates that a fault has occurred in the supply voltage to the Accelerator…

MBE 900/4000

MBE 900/4000 SID 232 Troubleshooting

Posted on October 17, 2023 by sam

Troubleshooting SID 232 Perform the following steps to troubleshoot SID 232:‪ 232 03 – Accelerator Pedal Supply Voltage Above Normal Troubleshoot a AP supply voltage…

MBE 900/4000

MBE 900/4000 SID 233 Troubleshooting

Posted on October 17, 2023 by sam

Troubleshooting SID 233 Perform the following steps to troubleshoot SID 233:‪ 233 12 – PLD-MR Failed or Programmed Incorrectly Troubleshoot a PLD-MR failed or programmed…

MBE 900/4000

MBE 900/4000 SID 233 – Pld-Mr Fault (Erroneous Data)

Posted on October 17, 2023 by sam

Description of SID 233 – Pld-Mr Fault (Erroneous Data) SID 233 indicates that a fault has occurred in the PLD-MR, making the PLD-MR data erroneous.‪…

MBE 900/4000

MBE 900/4000 SID 242 Troubleshooting

Posted on October 17, 2023 by sam

Troubleshooting SID 242 The following procedure will troubleshoot SID 242.‪ 242 12 – Cruise Control Switch SET and RES Contacts Closed at the Same Time…

MBE 900/4000

MBE 900/4000 SID 242 – Cruise Control Set/Resume Switch Fault

Posted on October 17, 2023 by sam

Description of SID 242 – Cruise Control Set/Resume Switch Fault SID 242 indicates that a fault has occurred in the cruise control Set/Resume Switch. See Figure…

MBE 900/4000

MBE 900/4000 SID 243 Troubleshooting

Posted on October 17, 2023 by sam

Troubleshooting SID 243 The following steps will troubleshoot SID 243.‪ 243 12 – Cruise Control Switch SET and RES Contacts Closed at the Same Time…

MBE 900/4000

MBE 900/4000 SID 243 – Cruise Control Set and Resume Switch Fault

Posted on October 17, 2023 by sam

Description of SID 243 — Cruise Control Set and Resume Switch Fault SID 243 indicates that a fault has occurred in the cruise control SET…

MBE 900/4000

MBE 900/4000 SID 248 – Pld-Mr DDEC-VCU Datalink Fault Description

Posted on October 17, 2023 by sam

Description of SID 248 – Pld-Mr DDEC-VCU Datalink Fault SID 248 indicates that a fault has occurred in the PLD-MR DDEC-VCU datalink.‪ The diagnostic condition…

Posts navigation

Previous Page Page 1 … Page 3 Page 4 Page 5 … Page 80 Next Page

Recent Posts

  • 12.7 Detroit Rod and Main Bearings Torque Specs
  • SPN 158 FMI 2: ECM Voltage Too Low
  • MBE 900/4000 PID 110 – Coolant Temperature Above Recommended Normal Operating Range
  • MBE 900/4000 PID 105 Troubleshooting
  • MBE 900/4000 PID 111 – Coolant Outside Normal Operating Range

Categories

  • Air Intake System
  • Cooling System
  • DD15
  • DD15 Operator Guide
  • DDEC III/IV Single ECM
  • DDEC MULTI ECM
  • Electrical
  • Engine
  • Engine
  • Engine not to Start
  • Excessive Crankcase Pressure
  • Excessive Exhaust Smoke
  • Excessive Oil Consumption
  • Excessive White Smoke
  • Exhaust System
  • Fuel System
  • Ignition System
  • Lubrication System
  • MBE 900/4000
  • Misfiring Cylinder
  • PTO
  • Series 60
  • SPN
  • Starting Difficulty
  • Troubleshooting

Pages

  • Contact Us
© Copyright 2025 – Detroit Diesel Troubleshooting Diagrams
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Privacy Policy